Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. bras. anestesiol ; 67(5): 521-526, Sept-Oct. 2017. tab
Article in English | LILACS | ID: biblio-897755

ABSTRACT

Abstract Background The triple airway maneuver insertion technique allowed faster insertion of the LMA. This study compared three different insertion techniques of the laryngeal mask airway-UniqueTM. Methods One hundred and eighty ASA I-II patients aged 18-65 years were included into the study. Patients were randomly allocated to the standard, rotational and triple airway maneuver (triple) group. In the standard group (n = 60), the LMA (Laryngeal Mask Airway) was inserted with digital intraoral manipulation. In the triple group (n = 60), the LMA was inserted with triple airway maneuver (mouth opening, head extension and jaw thrust). In the rotational group (n = 60), LMA was inserted back-to-front, like a Guedel airway. Successful insertion at first attempt, time for successful insertion, fiber optic assessment, airway morbidity and hemodynamic responses were assessed. Results Successful insertion at the first attempt was 88.3% for the standard, 78.3% for the rotational and 88.3% for the triple group. Overall success rate (defined as successful insertion at first and second attempt) was 93% for the standard, 90% for the rotational and 95% for the triple group. Time for successful insertion was significantly shorter in the triple group (mean [range] 8.63 [5-19]s) compared with the standard (11.78 [6-24]s) and rotational group (11.57 [5-31]s). Fiber optic assessment, airway morbidity and hemodynamic responses were similar in all groups. Conclusions Rotational and triple airway maneuver insertion techniques are acceptable alternatives. Triple airway maneuver technique shows higher overall success rates and allows shorter insertion time for LMA insertion and should therefore be kept in mind for emergent situations.


Resumo Justificativa A técnica de inserção com a manobra tripla das vias aéreas permitiu a inserção mais rápida da ML. Este estudo comparou três técnicas de inserção da máscara laríngea UniqueTM. Métodos Foram incluídos no estudo 180 pacientes ASA I-II, entre 18-65 anos. Os pacientes foram aleatoriamente designados para grupos de manobra das vias aéreas padrão, rotacional e tripla. No grupo padrão (n = 60), a máscara laríngea (ML) foi inserida com a técnica digital intraoral. No grupo tripla (n = 60), a ML foi inserida com a técnica de manobra tripla das vias aéreas (abertura bucal, extensão da cabeça e elevação da mandíbula). No grupo rotacional (n = 60), a ML foi inserida com a técnica de inserção de trás para frente, como uma cânula de Guedel. Inserção bem-sucedida na primeira tentativa, tempo de inserção bem-sucedida, avaliação por fibra óptica, morbidade das vias aéreas e respostas hemodinâmicas foram avaliados. Resultados O sucesso da inserção na primeira tentativa foi de 88,3% para o grupo padrão, 78,3% para o grupo rotacional e 88,3% para o grupo tripla. A taxa de sucesso global (definida como inserção bem-sucedida na primeira e segunda tentativas) foi de 93% para o grupo padrão, 90% para o grupo rotacional e 95% para o grupo tripla. O tempo de inserção bem-sucedida foi significativamente menor no grupo tripla (média [intervalo] 8,63 [5-19]s), em comparação com o grupo padrão (11,78 [6-24]s) e o grupo rotacional (11,57 [5-31]s). A avaliação por fibra óptica, a morbidade das vias aéreas e as respostas hemodinâmicas foram semelhantes em todos os grupos. Conclusões As técnicas de inserção rotacional e de manobra tripla das vias aéreas são opções aceitáveis. A técnica de manobra tripla das vias aéreas apresenta taxas mais altas de sucesso global e permite um tempo menor de inserção da ML e, portanto, deve ser considerada em situações de emergência.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Aged , Young Adult , Laryngeal Masks , Intubation, Intratracheal/methods , Equipment Design , Middle Aged
2.
International Eye Science ; (12): 1807-1811, 2017.
Article in Chinese | WPRIM | ID: wpr-641105

ABSTRACT

AIM: To evaluate the efficacy and safety of a new implant, Suprajet ( VSY Biotechnology, Istanbul, Turkey ) , which is developed for supraciliary and suprachoroidal drainage of aqueous humour. ·METHODS: Five rabbits were included in the study. One Suprajet shunt was implanted in one eye of each rabbit. Implantation was performed by a superior clear corneal incision through the anterior chamber into the suprachoroidal space. Proximal end of the implant was placed in the iris root resting against the scleral spur, distal end was placed in the suprachoroidal space. Rabbits were followed for 4wk. Preoperative and postoperative intraocular pressure ( IOP ) levels were measured with Tonopen AVIA. At last follow-up visit animals were sacrificed and eyes were enucleated. Macroscopic and histopathologic evaluation of the eyes were made. ·RESULTS:Mean preoperative IOP was 18. 6±6. 1 mmHg. Mean postoperative IOP was 8. 4 ± 1. 1 mmHg, at one week. At the 2nd week of the follow-up period one rabbit died. Thereafter, only 4 rabbits were followed. Mean postoperative IOP was 11. 0 ± 2. 8 mmHg at the 2nd week, 9. 50±3. 1 mmHg at the 3rd week and 11. 3 ±3. 3 mmHg at 4th week after the operation. When mean preoperative IOP was compared with the postoperative IOP values, only the IOP at the first week was found as significantly lower ( P=0. 042). There was no statistically significant difference between mean preoperative IOP level and mean IOP level at 2, 3 and 4wk postoperatively (P=0. 66, P=0. 66 and P=0. 102, respectively). As an intraoperative complication, minimal hyphema was noted in three eyes during the surgery. However, the next day hyphema cleared completely. Macroscopic evaluation of the enucleated material showed that in one eye the distal end of the implant was in the vitreous instead of suprachoroidal space, in the other 3 eyes the distal end of the implant was noted in the suprachoroidal space. In all eyes, proximal end of the implant was localized in the anterior chamber angle. Histopathologic evaluation of the enucleated eyes showed deposition of irregular collagen bundles and fibroplasia including numerous fibroblastic and histiocytic cells around the implant. ·CONCLUSION: This preliminary animal study showed that implantation of Suprajet in glaucoma is a promising procedure. Further studies are needed to evaluate its efficacy and safety profile.

SELECTION OF CITATIONS
SEARCH DETAIL